(21) Vibration galvanometer are generally used ……………
[A] As null – point detectors in ac bridges
[B] For measuring electric charges
[C] As null – point detectors in dc bridges
[D] For measuring power
Answer: As null – point detectors in ac bridges
(22) For the measurement of unknown inductance in terms of known capacitance, the suitable ac bridges are ………..
[A] Maxwell and Hay’s bridge
[B] Maxwell and Schering bridge
[C] Maxwell and Wien’s bridge
[D] Hay’s and Wien’s bridge
Answer: Maxwell and Hay’s bridge

DOWNLOAD CURRENT AFFAIRS PDF FROM APP

(23) Swamping resistance is a resistance made up of ………………
[A] Alloy of manganin and aluminium
[B] Alloy of aluminium and copper
[C] Alloy of nickel and cobalt
[D] Alloy of manganin and copper
Answer: Alloy of manganin and copper
(24) In a moving coil of a meter swamping resistance is added to ……….
[A] Reduce the temperature error
[B] Reduce the frequency error
[C] Reduce the power consumption
[D] All of these
Answer: Reduce the temperature error
(25) Induction type instruments are generally used as ……….
[A] Ammeter
[B] Wattmeter
[C] Voltmeter
[D] All of these
Answer: All of these
(26) Damping torque is the torque which acts on …………..
[A] Moving system of the instrument only when it is moving
[B] Stationary system of the instrument
[C] Moving system of the instrument only when it is stationary
[D] Stationary system of the instrument only when the moving system is moving
Answer: Moving system of the instrument only when it is moving
(27) Random errors in a measurement system are due to …………..
[A] Environmental changes
[B] Unpredictable effects
[C] Use of uncalibrated instrument
[D] Poor cabling practices
Answer: Unpredictable effects
(28) If the instrument is used in wrong manner while application, then it will results in ……….
[A] Systematic error
[B] Random error
[C] Instrument error
[D] None of the above
Answer: Instrument error
(29) The systematic errors of an instrument can be reduced by making ………….
[A] The sensitivity of instrument to environmental input as high as possible
[B] Systematic errors does not depend on the sensitivity of instrument
[C] The sensitivity of instrument to environmental input as low as possible
[D] None of these
Answer: The sensitivity of instrument to environmental input as low as possible
(30) The magnitude of environment – induced variation from the specified calibration condition is quantified by ………
[A] Sensitivity drift
[B] Zero drift
[C] Backlash
[D] Both (1) & (2)
Answer: Both (1) & (2)
31 The displacement measuring instruments is / are ………
[A] Potentiometer
[B] RVDT
[C] LVDT
[D] All of these
Answer: All of these
32 In fibre – optic level sensors, the amount of light loss depends on ………..
[A] Amount of light which is reflected back
[B] The proportion of cable that is not in the liquid
[C] Amount of light which is not reflected back
[D] The proportion of cable that is submerged in the liquid
Answer: The proportion of cable that is submerged in the liquid
33 For the measurement of pressure the instruments used can be ……….
[A] Electronic
[B] Mechanical
[C] Electro – mechanical
[D] All of these
Answer: All of these
34 The transformer ratio of the transformer depends upon the …………
[A] Power factor of secondary circuit
[B] Exciting current
[C] Secondary current
[D] All of these
Answer: All of these
35 Which of the following is detected using manometer devices?
[A] Density difference between manometric and measuring liquid
[B] pH difference between manometric and measuring liquid
[C] Pressure difference between manometric and measuring liquid
[D] None of the mentioned
Answer: Pressure difference between manometric and measuring liquid
36 Which of the following applications are suited for thin plate diaphragms?
[A] Static pressure only
[B] Dynamic pressure only
[C] Both static and dynamic pressure with large frequency
[D] Both static and dynamic pressure with small frequency
Answer: Both static and dynamic pressure with small frequency
37 Identify the proper sequence of valve actions for a three-valve manifold and bleed when taking a differential pressure transmitter out of service:
[A] Close one block valve, open equalizing valve, close other block valve, open bleed
[B] Open bleed, close one block valve, open equalizing valve, close other block valve
[C] Close one block valve, open bleed, close other block valve, open equalizing valve
[D] Open equalizing valve, open bleed, close both block valves (simultaneously)
Answer: Close one block valve, open equalizing valve, close other block valve, open bleed
38 A moving-coil permanent-magnet instrument can be used as flux-meter by ………………
[A] using a low resistance shunt
[B] using a high series resistance
[C] eliminating the control springs
[D] making control springs of large moment of inertia
Answer: eliminating the control springs
39 In rotary variable differential transformer, the mutual inductance between the primary and secondary coils varies …………
[A] Linearly with the angular displacement
[B] Non – linearly with the linear displacement
[C] Linearly with the linear displacement
[D] Non – linearly with the angular displacement
Answer: Linearly with the angular displacement
40 The household energy meter is ………..
[A] an indicating instrument
[B] a recording instrument
[C] an integrating instrument
[D] none of the above
Answer: an integrating instrument