61
A.C. network analyser is used to solve problems of
[A]
load flow
[B]
load flow and short-circuit
[C]
load flow and stability
[D]
load flow, short-circuit and stability
Answer: load flow, short-circuit and stability
62
Short-circuit currents are due to
[A]
single phase to ground faults
[B]
phase to phase faults
[C]
two phase to ground faults
[D]
any of these
63
The short circuit in any winding of the transformer is the result of
[A]
mechanical vibration
[B]
insulation failure
[C]
loose connection
[D]
impulse voltage
64
For which of the following protection from negative sequence currents is provided ?
[A]
Generators
[B]
Motors
[C]
Transmission line
[D]
Transformers
65
Relay is preferred for phase fault on short transmission line.
[A]
Induction type
[B]
Reactance
[C]
Impedance
[D]
None Of The Above
66
For which of the following ratings of the transformer differential protection is recommended ?
[A]
above 30 kVA
[B]
equal to and above 5 MVA
[C]
equal to and above 25 MVA
[D]
none of the above
Answer: equal to and above 5 MVA
67
The under voltage relay can be used for
[A]
generators
[B]
busbars
[C]
transformers
[D]
all of the above
68
The single phasing relays are used for the protection of
[A]
single phase motors only
[B]
two phase motors only
[C]
two single phase motors running in parallel
[D]
three phase motors
Answer: three phase motors
69
Which of the following parameter can be neglected for a short line ?
[A]
Inductance
[B]
Capacitance
[C]
Resistance
[D]
All Of The Above
70
Which of the following circuit breakers has high reliability and minimum maintenance ?
[A]
Air blast circuit breakers
[B]
Circuit breaker with SF6 gas
[C]
Vacuum circuit breakers
[D]
Oil circuit breakers
Answer: Circuit breaker with SF6 gas
71
Transmission line has reflection coefficient as one.
[A]
Open circuit
[B]
Short-circuit
[C]
Long
[D]
None of the above
72
The inverse definite mean time relays are used for over current and earth fault protection of transformer against
[A]
heavy loads
[B]
internal short-circuits
[C]
external short-circuits
[D]
all of the above
Answer: internal short-circuits
73
Air blast circuit breakers for 400 kV power system are designed to operate in
[A]
100 microsecond
[B]
50 millisecond
[C]
0.5 sec
[D]
0.1 sec
74
Series capacitors are used to
[A]
compensate for line inductive reactance
[B]
compensate for line capacitive reactance
[C]
improve line voltage
[D]
None Of The Above
Answer: compensate for line inductive reactance
75
If the fault occurs near the impedance relay, the VII ratio will be
[A]
constant for all distances
[B]
lower than that of if fault occurs away from the relay
[C]
higher than that of if fault occurs away from the relay
[D]
none of the above
Answer: lower than that of if fault occurs away from the relay
76
The torque produced in induction type relay (shaded pole structure) is
[A]
inversely proportional to the current
[B]
inversely proportional to the square of the current
[C]
proportional to the current
[D]
all of the above
Answer: inversely proportional to the square of the current
77
The inductive interference between power and communication line can be minimized by
[A]
transposition of the power line
[B]
transposition of the communication line
[C]
both (a) and (b)
[D]
increasing the distance between the conductors
78
The power loss is an important factor for the design of
[A]
transmission line
[B]
motor
[C]
generator
[D]
feeder
Answer: transmission line
79
H.R.C. fuse, as compared to a rewirable fuse, has
[A]
no ageing effect
[B]
high speed of operation
[C]
high rupturing capacity
[D]
all of the above
80
The fuse rating is expressed in terms of
[A]
current
[B]
voltage
[C]
VAR
[D]
kVA
Please share this page