![In a laboratory, a flow experiment is performed over a hydraulic structure The measured values](https://www.gkseries.com/blog/wp-content/uploads/2023/09/In-a-laboratory-a-flow-experiment-is-performed-over-a-hydraulic-structure-The-measured-values-.jpg)
Q. In a laboratory, a flow experiment is performed over a hydraulic structure. The measured values of discharge and velocity are 0.05 m3/s and 0.25 m/s, respectively. If the full scale structure (30 times bigger) is subjected to a discharge of 270 m3/s, then the time scale (model to full scale) value (up to two decimal places) is
Ans: 0.15-0.25
Sol:
![](https://www.gkseries.com/blog/wp-content/uploads/2023/09/Screenshot-926.png)