The average velocity v of flow of clear water in a 100 cm (inner) diameter tube is measured

Q. The average velocity v of flow of clear water in a 100 cm (inner) diameter tube is measured using the ultrasonic flow meter as shown in the figure. The angle q is 45°. The measured transit times are t1 = 0.9950 ms and t2 = 1.0000 ms. The velocity v (in m/s) in the pipe is (up to one decimal place) _.

Ans: 4.8 – 5.2

Take Mock Tests

Government Schemes Mock Test Start Test!
Political Science Mock Test – 42 Start Test
History Test – 190 Start Test
Quantitative Aptitude Test Start Test!
Data Interpretation - Mock Test Start Test!
General Awareness - Mock Test Start Test!
Reasoning Ability - Mock Test Start Test!
We will be happy to hear your thoughts

Leave a reply

Gkseries.com
Logo
Register New Account