A piezoelectric transducer with sensitivity of 30 mV/kPa is intended to be used in the range of 0 kPa to 100 kPa. The readout
Q. A piezoelectric transducer with sensitivity of 30 mV/kPa is intended to be used in the range of 0 kPa to 100 kPa. The readout circuit has a peak noise amplitude of 0.3 mV and measured signals over the full pressure range are encoded with 10 bits. The smallest pressure that produces a non-zero output, in units of Pa, is approximately
(A) 10 (B) 100 (C) 240 (D) 300
Ans: 100
Sol:
Given that,
Sensitivity = 30 mV/kPa
Range = 0 kPa to 100 kPa
Full scale voltage = 30 × 10-3 × 100 = 3 V
Noise of readout circuit = 0.3 mV
Vref = 3.0003V
Number of bits = n = 10