A process which is in a state of statistical control (within ± 3s ) has an estimate of standard deviation (s) 2 mm
Q. A process which is in a state of statistical control (within ± 3s ) has an estimate of standard deviation (s) 2 mm. The specification limits for the corresponding product are 120 ± 8 mm. When process mean shifts from 118 mm to 122 mm with no change in process standard deviation, the difference in process capability index Cpk is
Ans: 0
Sol: