![A process which is in a state of statistical control (within ± 3s ) has an estimate of standard deviation (s) 2 mm](https://www.gkseries.com/blog/wp-content/uploads/2023/09/A-process-which-is-in-a-state-of-statistical-control-within-±-3s-has-an-estimate-of-standard-deviation-s-2-mm.jpg)
Q. A process which is in a state of statistical control (within ± 3s ) has an estimate of standard deviation (s) 2 mm. The specification limits for the corresponding product are 120 ± 8 mm. When process mean shifts from 118 mm to 122 mm with no change in process standard deviation, the difference in process capability index Cpk is
Ans: 0
Sol:
![](https://www.gkseries.com/blog/wp-content/uploads/2023/09/Screenshot-856.png)