In a laboratory, a flow experiment is performed over a hydraulic structure The measured values

Q. In a laboratory, a flow experiment is performed over a hydraulic structure. The measured values of discharge and velocity are 0.05 m3/s and 0.25 m/s, respectively. If the full scale structure (30 times bigger) is subjected to a discharge of 270 m3/s, then the time scale (model to full scale) value (up to two decimal places) is                                                        

Ans: 0.15-0.25

Sol: