(1)
Hysteresis of an instrument means:
[A]
The change in the same reading when input is first increased and then decreased
[B]
The reliability of the instrument
[C]
The repeatability of the insrument
[D]
The inaccuracy due to change in temperature
Answer: The change in the same reading when input is first increased and then decreased
(2)
In which part of the scale does the pointer indicate more accurately
[A]
In the first third of the cycle
[B]
In the first half of the cycle
[C]
In about middle of the scale
[D]
In the last third of the cycle
Answer: In about middle of the scale
(3)
A 150 V moving iron voltmeter of accuracy class 1.0 reads 75 V when used in a circuit under a standard conditions. The maximum possible percentage error in the reading is:
[A]
0.5
[B]
1.0
[C]
2.0
[D]
4.0
(4)
The moving iron voltmeters are likely:
[A]
To indicate the same value of the ac as on dc
[B]
To indicate higher value of ac than on dc
[C]
To indicate lower value of ac than on dc
[D]
The moving iron instruments should not be used for dc measurment
Answer: To indicate lower value of ac than on dc
(5)
Hay’s Bridge is suitable for the measurement of:
[A]
Inductances with Q>10
[B]
Inductances with Q<10
[C]
Capacitors with high dissipation factor
[D]
Capacitors with low dissipation factor
Answer: Inductances with Q>10
(6)
The ballistic galvanometer is usually lightly damped so that:
[A]
It may oscillate
[B]
It may remain stable
[C]
Amplitude of the first swing is large
[D]
Amplitude of the first swing is small
Answer: Amplitude of the first swing is large
(7)
Magnetic materials can be tested by:
[A]
Self inductance bridge
[B]
Cambell’s mutual inductance bridge
[C]
AC potentiometer
[D]
All the above
(8)
In CRO astigmatism is:
[A]
Source of generating fast electrons
[B]
Media for absorbing secondary emission electrons
[C]
An additional focus control
[D]
Time-delay control in the vertical deflection system
Answer: An additional focus control
(9)
Moving iron and PMMC instruments can be distinguished from each other by looking at:
[A]
Pointer
[B]
Terminal size
[C]
Scale
[D]
Scale range
(10)
The deflection of hot-wire instrument depends on:
[A]
Instantaneous value of alternating current
[B]
Average value of current
[C]
RMS value of the alternating current
[D]
Voltage
Answer: RMS value of the alternating current
(11)
The damping torque must operate only when the moving system of the indicating instrument is:
[A]
Actually moving
[B]
Stationary
[C]
Just starting to move
[D]
Near its full deflection
(12)
Air friction damping is used in the instruments which is:
[A]
Moving iron
[B]
Moving coil
[C]
Induction
[D]
Hot wire
(13)
An instrument that is capable of measuring only dc is:
[A]
Moving coil
[B]
Moving iron
[C]
Thermo couple
[D]
None of the above
(14)
A ballistic galvanometer is used to measure:
[A]
Charge
[B]
Current
[C]
Voltage
[D]
Frequency
(15)
For measuring emf of a standard cell we use:
[A]
Galvanometer
[B]
Potentiometer
[C]
Zener reference
[D]
Electro-dynamic voltmeter
(16)
Introduction of dielectric:
[A]
Increases the capacitance
[B]
Reduces the breakdown voltage
[C]
Reduces the mechanical voltage
[D]
Increases the size of the capacitor
Answer: Increases the capacitance
(17)
Which of the following instruments have least torque/weight ratio:
[A]
Dynamometer type
[B]
PMMC
[C]
Attraction type moving iron
[D]
Repulsion type moving iron
(18)
The instrument having its deflection depends upon average value is:
[A]
Moving iron
[B]
Hot wire
[C]
Rectifier type
[D]
Induction type
(19)
Which of the following instruments can be used for full scale deflection of 300o:
[A]
PMMC
[B]
Induction type
[C]
Hot wire
[D]
Electrostatic
(20)
A Ohmmeter is basically:
[A]
A ammeter
[B]
A voltmeter
[C]
A multimeter
[D]
None of the above